BAUR
Cable Fault Location
Titron® is a combination of the words Titanium and Electron
The New Dimensions in Cable Fault Location Key Features
- New intuitive operational concept
- BAUR GeoBase map
- GIS Data import/export
- Smart Cable Fault Location Guide
- Fully automatic system control
- BAUR Remote App
- Remote support for application & service
Transcable 4000/S 32-3 cable test van is a 32 kV cable fault location system in 3-phase version. The system is controlled with the MGS semi-automatic control unit. The high voltage switch unit is maintenance-free and fully safe to touch.
Transcable 4000/S 70-3 cable test van varies in comparison with the transcable 32 kV – 3S in the 70 kV voltage level. The system is controlled with the MGS semi-automatic control unit. The high voltage switch unit is 3-phase, air and solid matter insulated and safe to touch.
Transcable 4000/A 80-3 cable test van is equipped with an automatic control system. The high voltage switch unit is enclosed and is actuated electrically with the fully automatic KE 3 control unit.
Transcable 4000/S 110-1 cable test van is a 110 kV cable fault location system in single-phase version. The system is actuated with the semi-automatic MGS control unit. The high voltage switch unit is single-phase, up to 32 kV, the 110 kV switching level is designed as air-insulated ceiling switch.
Fault location system for medium voltage networks
Syscompact 2000 / 32 kV
- Cable testing, pre-location, and pinpointing
- Voltage range 8/16/32 kV step less adjustable
- Energy up to 3000 J
- IRG 2000
Fault location system for medium voltage networks
Syscompact 4000 / 32 kV
- Cable testing, pre-location, and pinpointing
- Voltage range 8/16/32 kV step less adjustable
- Energy up to 3000 J
- IRG 4000
The innovative, multifunctional solution for a fast, precise, and efficient pinpointing of cable faults
- Unique user comfort due to the wireless Bluetooth connection between the control unit, ground microphone and headphones
- User guidance towards the fault by the precise 3D left/right navigation and direction indication
- Excellent acoustic quality and range supported by the unique noise cancellation technology ANS (Adaptive Noise Suppression)
- Time saving by using the cable track data and the pre-located fault position in combination with GPS and the BAUR Fault Location App
Very Low Frequency (VLF)
The new cable condition evaluation generation
- Cable testing and dissipation factor diagnostics in one device
- For testing medium-voltage cables and electrical equipment (generators, transformers, and switch gear)
- For cable sheath testing
- Automatic testing and diagnostic sequences
- Compact dimensions and lightweight
- Max. test voltage 24 kV rms / 34 kV peak
- Voltage shapes: VLF truesinus®, VLF square wave voltage and DC voltage
The new cable condition evaluation generation
- Cable testing and dissipation factor diagnostics in one device
- For testing medium-voltage cables and electrical equipment (generators, transformers, and switch-gear)
- For cable sheath testing
- Automatic testing and diagnostic sequences
- Compact dimensions and lightweight
- Max. test voltage 44 kV rms / 62 kV peak
- Voltage shapes: VLF truesinus®, VLF square wave voltage and DC voltage
Portable, high performance test generator with VLF truesinus® technology
- 3 voltage shapes in one device: VLF truesinus®, VLF square wave and DC voltage
- For medium-voltage cables of up to 50 kV operating voltage Cable testing, fault conditioning, cable sheath testing.
- VLF truesinus® up to 38 / 57 kV rms (PHG 70 / PHG 80)
- VLF square wave up to 57 / 80 kV (PHG 70 / PHG 80)
- DC voltage up to ±70 / ±80 kV (PHG 70 / PHG 80)
View more: PHG 70 portable / PHG 80 portable
Universal test and diagnostics system – flexible, modular, extendable
- Cutting-edge testing and diagnostics technology: VLF truesinus®
- High performance test generator with three voltage shapes
- Comprehensive cable analysis by means of partial discharge and dissipation factor measurement
- VLF truesinus® up to 38 / 57 kV rms (PHG 70 / PHG 80)
- VLF square wave voltage up to 57 / 80 kV (PHG 70 / PHG 80)
- DC voltage up to ±70 / ±80 kV (PHG 70 / PHG 80)
View more: PHG 70 TD PD / PHG 80 TD PD
AC/DC High Voltage Test
Compact, mobile, and versatile
- Compact device for DC voltage testing with negative polarity
- Continuously adjustable output voltage
- Perfect for mobile use weight 16.5 kg
PGK 50 : DC 0 – 50 kV ; PGK 80 : DC 0 – 80 kV
Small, lightweight, and powerful
- Compact device for DC voltage testing with negative polarity
- Sensitive current measurement for recording extremely small insulation currents
- Easily portable thanks to practical case
The BAUR PGK AC/DC HV test sets are used to generate continuously adjustable test voltages:
- DC voltages with positive or negative polarity
- AC voltages at mains frequency
PGK 70 HB / PGK 70/2,5 HB: Test voltages up to AC 55 kV rms or DC ±70 kV
PGK 110 HB / PGK 110/5 HB: Test voltages up to AC 80 kV rms or DC ±110 kV
PGK 150 HB / PGK 150/5 HB: Test voltages up to AC 110 kV rms or DC ±150 kV
PGK 260 HB / PGK 260/5 HB: Test voltages up to AC 190 kV rms or DC ±260 kV